FAILURE MODES

What happens when the sensor has a problem

Mirroring / TAP

Nothing for the process: the sensor receives a copy. On power loss, reboot or hardware failure you only lose visibility, reported by the loss-of-visibility alert.

Inline, listen only

The bridge has no IP address and cannot speak IP into the process network; forwarded traffic never touches the packet filters; no blocking rules on the data path, verified at every boot. On a software hang the sensor reboots itself (kernel.panic=10) and the bridge returns in about 2 minutes. On power loss or hardware failure the link is interrupted; therefore: inline (an IP-less bridge between router and switch) only for evaluations, with the client's written consent, or with a hardware-bypass network card.

Management

Out of band only: own 4G modem and a dedicated encrypted tunnel to a server dedicated to the client. No open port in the client's network, no dependency on it.

The 4G modem is not a path into the process network

The capture interfaces only receive: they have no IP address, emit no frames (0 frames measured) and there is no routing between them and the modem; nothing in the client's network can be reached from the modem. If your policy does not allow a cellular modem next to the process network, there are two alternatives: management through your DMZ, or a fully offline mode — the sensor collects with no external link and the data is retrieved at the end, on removal.

Data

Raw data stays on the sensor and on the dedicated server; at the end of the evaluation it is deleted with an evidence log within 5 working days of delivering the report.

Values measured at the inline test of 5 November 2026 (our office)

Ports1000/full, 0 errors
Packets dropped by the detection engine0
Frames emitted by the sensor into the monitored network0 in 120 s
Recovery after a full reboot4 min 53 s, modem included
Bridge recovery after a software hangabout 2 minutes

Latency added by the inline bridge and switch-over time on a production network will be published after the first client installation; we do not show estimated values.